X12DPI-NT6-P,825BTS-R1K03LPP1, 2U X12 SATA Mainstream Se

SYS-620P-TRT

For this server, it's best to contact us for a fully validated, configured model. You can also add desired components to your cart, select "pay by bank transfer" at checkout, and we'll try to fulfill your wishes. We'll configure your system as closely as possible and send an updated quote with a validated system shortly. You can then decide if you want this configuration. The final payment method will be agreed upon after you accept the configuration.

https://safeconsulting.no/web/image/product.template/10443/image_1920?unique=f7d9088

kr 23 165,77 23165.77 NOK kr 23 165,77

kr 23 165,77

Not Available For Sale

    Denne kombinasjonen eksisterer ikke.

    Summary Description

    The Supermicro SYS-620P-TRT is a powerful 2U server featuring dual socket P+ (LGA-4189) 3rd Gen Intel Xeon Scalable processors, supporting up to 4TB of memory. Ideal for virtualization, enterprise servers, and data center applications.

    Key Features

    • Dual sockets P+ (LGA-4189) 3rd Gen Intel® Xeon® Scalable processors;CPU TDP supports Up to 270W TDP;3 UPI up to 11.2 GT/s
    • Up to 4TB 3DS ECC RDIMM, DDR4-3200MHz, Up to 4TB 3DS ECC LRDIMM, DDR4-3200MHz ;- Up to 4TB Intel® Optane™ Persistent Memory 200 Series, DDR4-3200MHz, in 18 DIMM slots (P1-DIMMB2 and P2-DIMMB2 are reserved for Intel® Optane Persistent Memory 200 Series only)
    • 4 PCIe 4.0 x16 Low Profile (LP);2 PCIe 4.0 x8 Low Profile (LP)
    • Dual  10GBase-T LAN with Intel® X550 Ethernet Controller
    • 3 heavy duty Hot-swappable 13.5K RPM Middle Cooling Fans with optimal fan speed control;1 air shroud
    • 1200W Redundant Power Supplies Titanium level 100-240Vac and 200-240 Vdc
    • 1 rear VGA, 1 Type A port, 2 COM Ports (1 front; 1 rear) and 6 USB ports (2 front USB 2.0 and 4 rear USB 3.0)

    Key Applications

    • Virtualization
    • Enterprise Server
    • Data Center Optimized
    • Application and data serving
    • Model analysis
    • Compute Intensive Applications

    Description

    The Supermicro SYS-620P-TRT offers a plethora of features for demanding applications. Equipped with dual 3rd Gen Intel Xeon Scalable processors, it supports up to 4TB of memory, and provides multiple I/O and expansion options including PCIe 4.0 slots. It boasts advanced cooling systems with hot-swappable fans and redundant power supplies, ensuring optimal performance and reliability. Designed for enterprise environments, the SYS-620P-TRT is perfect for data centers, virtualization, and compute-intensive applications.

    Product Specifications

    Specification Details
    Product SKUs
    SKUs
    • SuperServer SYS-620P-TRT
    Motherboard
    Installed Motherboard
    • Super X12DPi-NT6
    Processor
    CPU
    • Dual Socket P+ (LGA-4189)
    • 3rd Gen Intel® Xeon® Scalable processors
    Core Count
    • Up to 36C/72T; Up to 60MB Cache per CPU
    Note
    • Supports up to 270W TDP CPUs (Air Cooled)
    System Memory
    Memory
    • Slot Count: 16 DIMM slots
    • Max Memory (2DPC): Up to 4TB 3200MT/s ECC DDR4 RDIMM/LRDIMM
    • Supports Intel® Optane™ persistent memory 200 series
    On-Board Devices
    Chipset
    • Intel® C621A
    Network Connectivity
    • 2 RJ45 10GbE
    Input / Output
    LAN
    • 1 RJ45 1 GbE Dedicated BMC LAN port(s)
    USB
    • 2 USB 2.0 port(s) (front)
    • 4 USB 3.0 port(s) (rear)
    Video
    • 1 VGA port(s)
    DOM
    • 2 Super DOM (Disk on Module) port(s)
    System BIOS
    BIOS Type
    • AMI 32MB SPI Flash EEPROM
    Management
    Software
    • SuperCloud Composer
    • Supermicro Server Manager (SSM)
    • Supermicro Update Manager (SUM)
    • Supermicro SuperDoctor® 5 (SD5)
    • Super Diagnostics Offline (SDO)
    • Supermicro Thin-Agent Service (TAS)
    • SuperServer Automation Assistant (SAA) New!
    Power configurations
    • ACPI/APM Power Management
    Security
    Hardware
    • Trusted Platform Module (TPM) 2.0
    • Silicon Root of Trust (RoT) – NIST 800-193 Compliant
    Features
    • Cryptographically Signed Firmware
    • Secure Boot
    • Secure Firmware Updates
    • Automatic Firmware Recovery
    • System Lockdown
    PC Health Monitoring
    CPU
    • Monitors for CPU Cores, Chipset Voltages, Memory
    • 4+1 Phase-switching voltage regulator
    FAN
    • Fans with tachometer monitoring
    • Status monitor for speed control
    • Pulse Width Modulated (PWM) fan connectors
    Temperature
    • Monitoring for CPU and chassis environment
    • Thermal Control for fan connectors
    Chassis
    Form Factor
    • 2U Rackmount
    Model
    • CSE-825BTS-R1K23LPP1
    Dimensions and Weight
    Height
    • 3.5" (89 mm)
    Width
    • 17.2" (437 mm)
    Depth
    • 25.5" (647 mm)
    Package
    • 11.4" (H) x 26.7" (W) x 34.5" (D)
    Weight
    • Gross Weight: 69 lbs (31.2 kg)
    • Net Weight: 36.38 lbs (16.5 kg)
    Available Color
    • Black
    Front Panel
    LED
    • HDD activity
    • Network activity
    • Power status
    • System information (overheat/UID)
    Buttons
    • Power On/Off
    • System Reset
    Expansion Slots
    PCI-Express (PCIe) Configuration
    Default:
    • 2 PCIe 4.0 x8 LP slots
    • 4 PCIe 4.0 x16 LP slots

    Drive Bays / Storage
    Drive Bays Configuration
    Default: Total 8 bays:
    • 8 front hot-swap 3.5" SAS*/SATA drive bays

    Option A: Total 10 bays:
    • 8 front hot-swap 3.5" SAS*/SATA drive bays
    • 2 front fixed 3.5" NVMe*/SATA* drive bays

    • (*NVMe/SAS/SATA support may require additional storage controller and/or cables, please see the optional parts list for details)
    M.2
    • 1 M.2 NVMe slot (M-key)
    Peripheral Bays
    • 1 slim DVD bay (optional)
    System Cooling
    Fans
    • 3 heavy duty fans with optimal fan speed control
    Power Supply
    1x 1200W Redundant Titanium Level (96%) power supply
    Dimension (WxHxL):
    • 76 x 40 x 336 mm

    AC Input:
    • 1000W: 100-127Vac / 50-60Hz
    • 1200W: 200-240Vac / 50-60Hz
    • 1200W: 200-240Vdc / 50-60Hz (for CCC only)

    +12V:
    • Max: 83A / Min: 0A (100Vac-127Vac)
    • Max: 100A / Min: 0A (200Vdc-240Vdc)
    • Max: 100A / Min: 0A (200Vac-240Vac)

    5V SB:
    • Max: 4A / Min: 0A

    Output Type:
    • Backplanes (gold finger)

    Operating Environment
    ROHS
    • RoHS Compliant
    Environmental Spec.
    • Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F)
    • Non-operating Temperature: -40°C to 60°C (-40°F to 140°F)
    • Operating Relative Humidity: 8% to 90% (Non-Condensing)
    • Non-operating Relative Humidity: 5% to 95% (Non-Condensing)
    General
    Standard Parts (Parts Included)

    Standard Part List

    Part Number Quantity Description
    Motherboard / Chassis
    MBD-X12DPi-NT61Super X12DPi-NT6 Motherboard
    CSE-825BTS-R1K23LPP112U Chassis
    Backplane
    BPN-SAS3-825TQ12U 8-Slot 12G Backplane for 8x3.5" SAS/SATA HDD/SSD
    Cable
    CBL-0343L-01230AWG IPASS/4SATA 76/66/54/45CM W/SB
    CBL-0071L1ROUND 16 TO 16 PIN RIBBON FP CABLE 30"L, LF
    CBL-PWCD-0160-IS2PWCD,US,NEMA5-15P TO IEC60320 C13,6FT,16AWG,RoHS/REACH
    CBL-PWEX-10783PWEX,FAN,1X4/P2.5 TO 1X4/P2.54,20CM,22AWG,5A/PIN,RoHS
    Drive Tray(s)
    MCP-220-00007-011Black USB/COM port tray for SC825, 836
    MCP-220-00023-011Black USB dummy tray support 1x 2.5" slim HDD for SC825, 836
    MCP-220-00075-0B8Black gen 5.5 hot-swap 3.5" HDD tray
    MCP-220-82502-0B2Black fixed 3.5\" HDD tray or FDD dummy tray
    MCP-290-82607-0N1826B/216B rear dummy cover for 2 X 2.5" HDD cage,RoHS
    Parts
    MCP-260-00042-0N1STD I/O shield for X9 socket R server MB with Gasket.
    Manual
    MNL-2241-QRG1SYS-620P-TR(T) Quick Reference Guide
    Software
    SFT-OOB-LIC1License key for enabling OOB BIOS management
    Heatsink / Retention
    SNK-P0078P12U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms
    SNK-P0078PC12U Passive CPU Heat Sink w/ a Side Air Channel for X12 Generation Intel Whitley and Cedar Island Platforms
    *Power Supply
    PWS-1K23A-1R2AC-DC 1200W, Titanium Level, Redundancy, 1U, PMBUS 1.2, +12V/+5Vsb, 336x76x40 mm,HF,RoHS/REACH
    *Power Distributor
    PDB-PT825-S88241SC825 24PIN REDUNDANT PWR DISTRIBUTOR W/ SHORT CBL
    *Fan
    FAN-0206L4380x80x38 mm, 13.5K RPM, Middle Cooling Fan for 2U and above Servers
    *Front Panel
    FPB-FP836-D1Front control board Dual color LED(FP836-D)forSC823M,825,825
    *Rear Window
    MCP-240-82608-0N1216B/826B LP rear window,RoHS/REACH,PBF
    *Peripheral Drive
    MCP-290-00007-011Black DVD dummy cover for SC825, 836
    *Rail Set
    MCP-290-00053-0N1Rail set, quick/quick, default for 2,3U 17.2"W
    MCP-290-00060-0N1Threaded rail adapter default for round hole rack
    *Air Shroud
    MCP-310-29001-0N1SC825/826/216/213 Intel DP X9,X8 air shroud 13.68x13/12x13

    Optional Part List

    Part Number Quantity Description
    Optional Gen3 8-ports SAS Raid controller kit for SYS-620P-TRT
    1x AOC-S3108L-H8IR or AOC-S3108L-H8IR-16DD + 2x CBL-SAST-0699 ( or 2x CBL-SAST-0556)1Convert 8x hotswap SATA drives to SAS drives
    Optional Gen4 8-ports SAS Raid controller kit for SYS-620P-TRT
    1x AOC-S3908L-H8IR-P or AOC-S3908L-H8IR-16DD-P or AOC-S3908L-H8IR-32DD-P + 1x CBL-SAST-1270S-1001Convert 8x hotswap SATA drives to SAS drives
    Optional parts needed to support 2x fixed NVMe drives
    1x CBL-SAST-0953 (Slimline x8 to PCIe 2x SFF-8639 Power) and 2x MCP-110-82501-0N11x MCP-110-82501-0N can support 1x 2.5 inch NVMe fixed drives and 1x CBL-SAST-0953 can support 2x 2.5 inch NMVe drives
    Optional parts needed to support 2x fixed SATA drives
    2x CBL-0044L(SATA CABLE 61CM FLAT S-S PBF.26AWG flat)  and 1x CBL-0082L (Y split , big 4 pin to two RA SATA power extension 15cm, 18AWG)11x CBL-0044L can support 1x 2.5 inch SATA drives and 1x CBL-0082L can support 2x 2.5 inch SATA drives
    Optional parts needed to support 2x Rear hotswap SATA drives
    1x MCP-220-82616-0N, (2.5x2 Hot-swap 12G rear HDD kit w/ fail LED for 216B/826B/41) and 1x CBL-SAST-0388L-02, 30AWG Ipass to 4SATA (90/90/70/70CM W/ 90CM SB);11x CBL-SAST-0388L-02 has 4 SATA ports, but the rear drive kit MCP-220-82616-0N can only support 2x 2.5 inch SATA drives, so two SATA ports are lost as a result
    use 1x BTR-TFM8G-LSICVM02 and 1x BKT-BBU-BRACKET-05  with AOC-S3108L-H8IR-16DD or AOC-S3108L-H8IR
    use 1x BTR-TFM8G-LSICVM02 and 1x BKT-BBU-BRACKET-05  with AOC-S3108L-H8IR-16DD or AOC-S3108L-H8IR1SuperCap and mounting bracket used for SAS raid controllers